Skip to content
The Cyano Codex
Choose language

Cyanotype with a UV lamp: how to expose without sun

To make cyanotypes without sun, all you need is an ultraviolet (UV) lamp placed over the frame, always at the same distance, and a test strip that gives you the time for that lamp. Here’s the setup, which wavelength to use, what to make of nail lamps and blacklights, and how to protect your eyes.
Section
Exposure
Reviewed
Reading time
16 min
Sources
22
Level
Beginner (level 1 of 3)

As an Amazon Associate I earn from qualifying purchases. How we fund the site

Ultraviolet LED lamp hanging over a contact printing frame with a faint violet glow in a dim room
Plate 1The lamp does the work on its own, pointing down.
Time
Setup and testing in one session; your test strip sets the exposure
Level
Beginner
Materials
9
Steps
6

In short

  • For the same energy, a 365 nm lamp performs better than a 395–405 nm one.
  • Wavelength doesn’t predict the time: power and distance also change the dose.
  • With the classic formula and a UV lamp, Mike Ware estimates exposures of about 20–30 minutes.
  • Fix the distance, measure it and make a test strip with that lamp before the final print.
  • Every nail lamp emits a different spectrum: they can work for small pieces, with testing.
  • Don’t look at the lamp, switch it on with the print already in place, and wear UV-blocking safety glasses.

Safety: Turn the lamp on only once the print is in place, don’t look at it, and wear UV-blocking safety glasses. More on safety

Safety: Use only 365 nm UVA lamps: UVC germicidal lamps injure eyes and skin in seconds. More on safety

Materials list

Check off what you already have on the table. The “Amazon” links are affiliate links.

To expose
To develop

Your check marks are saved only in this browser. No account needed.

On this page (6 sections)
  1. Can you make cyanotypes with a UV lamp?
    1. 1. Choose a lamp you can measure
    2. 2. Set up your station and fix the distance
    3. 3. Put the print in the frame
    4. 4. Make a test strip with that lamp
    5. 5. Expose the print and watch the color
    6. 6. Switch off, remove the print and wash it
  2. 365 or 395 nm: which wavelength to use
  3. Can you make cyanotypes with a nail lamp?
  4. Does a blacklight work?
  5. How to protect your eyes and skin with the lamp
  6. If something goes wrong

Can you make cyanotypes with a UV lamp?#

Yes. Cyanotype responds to ultraviolet light, and a UV lamp can stand in for the sun at any hour and in any season. The lamp goes over the frame, pointing down, at a fixed distance; the exposure time comes from a test strip made with that same lamp1.

It’s the way to make cyanotypes without sun, and it has one advantage over natural light: it’s repeatable. The dose of light the print receives is intensity times time2, and with the same lamp at the same distance that intensity doesn’t change from one day to the next. The general approach to cyanotype exposure time applies here too; what changes is the setup.

The sources give these reference times with a lamp, each for its own formula:

Published UV lamp times, by formula
Formula Lamp Published time
Classic, Ware’s traditional recipe UV lamp About 20–30 min3
Classic 125 W UV lamp at about 45 cm About 30 min, as a basic guide4
Ware’s New Cyanotype Average UV source About 2–4 min5
Ware’s Simple Cyanotype 365 nm UVA lamp About 5–10 min6

These are starting points, not times to copy. Ware adds that, with the traditional formula, exposures of thirty minutes or more under a typical UV source are not unusual5.

  1. Step 1: Choose a lamp you can measure

    Before buying a lamp, or using one you already have, check three things in its manual: the wavelength, the voltage and the plug. The wavelength to go for is 365 nm, because, for the same energy, it performs better than 395–405 nm1. The voltage and plug have to match the mains supply in your country, and the area it lights has to be larger than your format.

    If the manual states the lamp’s photobiological risk group under the EN 62471 standard, follow it: according to the European scientific committee SCENIHR, groups 0 and 1 pose no hazard under normal conditions of use, and group 3 includes lamps that are hazardous even with brief exposures7. The buying criteria, including what to look for on an Amazon listing, are in the guide to UV lamps for cyanotype.

    How to tell it’s going well: you have the wavelength, voltage and plug confirmed in writing, not just in the listing title.

    Safety: Use only 365 nm UVA lamps: UVC germicidal lamps injure eyes and skin in seconds. More on safety

  2. Step 2: Set up your station and fix the distance

    Mount the lamp on a stable stand, pointing down, above the spot where the frame will go. The distance determines the intensity that reaches the paper: closer means more irradiance and less time; farther, the opposite1. Choose a distance that covers the whole format, measure it with a tape measure and write it down.

    As a reference, the Science and Media Museum gives, for the classic formula, a 125 W lamp at 18 inches, about 45 cm, for about 30 minutes4. It isn’t a rule, because it doesn’t specify the type of lamp: it shows you the order of magnitude. The museum also points to heat buildup as a reason times vary4, so leave air space around the lamp and the frame.

    Work in a dimly lit room or, at least, with no direct sun on the table, and keep the lamp well away from the water tray. That way the only light that counts is the lamp’s.

    How to tell it’s going well: the lamp stays put, the distance is written down and the light falls over the whole frame.

    Common mistake: raising or lowering the lamp between the test and the print. Changing the distance changes the dose, and the test time no longer applies.

  3. Step 3: Put the print in the frame

    Assemble the print with the lamp off. From the bottom up: a rigid board, the paper with the coated side up, the negative or the objects, and the glass, firmly clamped. If you’re using a digital negative, put the ink side against the paper, which is the orientation the image is flipped for8.

    Check the paper’s color first: it should be pale yellow. If it already looks green or blue, it has chemical fog and the highlights will come out fogged9. Setting up the glass, the pressure and a homemade frame are covered on their own page: glass for cyanotype.

    How to tell it’s going well: the negative doesn’t move when you tilt the frame, and there’s no air between it and the paper.

    Safety: Turn the lamp on only once the print is in place, don’t look at it, and wear UV-blocking safety glasses. More on safety

  4. Step 4: Make a test strip with that lamp

    With the station set up, expose a strip of the same paper in sections, with times that double from one section to the next. This is the classic test strip method, and the right time may fall between two sections10. Choose your unit so that the published time for your formula, from the table above, falls around the middle of the series.

    With a lamp there’s a safer way to do it: switch it off each time you move the card covering the sections. Time only counts while it’s on, and this way you don’t put your hands in the beam.

    Wash the strip, let it dry and pick the section that gives the blue you want in the shadows without fogging the highlights. If in doubt, go with the longer one: Jacquard advises overexposing rather than underexposing11. The full method, with the diagram, is in the test strip section of the exposure page.

    How to tell it’s going well: the sections run from pale blue to the deepest, and at least one is beyond the one you choose.

  5. Step 5: Expose the print and watch the color

    Switch on the lamp with the print already in place, start the timer with the time from your test and step out of the beam. The lamp does the work on its own. If you stay nearby, wear UV-blocking safety glasses, ideally with a U number under ANSI Z87.1, the US standard for eye protection12.

    You can see the image as it forms. With the classic formula, the sign that it’s enough is when the shadows look bronzed4; with Ware’s formulas, when the deepest shadows reverse to a pale bluish gray6. To check it, switch off the lamp first and open one half of the back, if your frame is hinged5.

    How to tell it’s going well: the exposed areas have clearly darkened and the covered areas are still yellow.

    Safety: Turn the lamp on only once the print is in place, don’t look at it, and wear UV-blocking safety glasses. More on safety

  6. Step 6: Switch off, remove the print and wash it

    Switch off the lamp before opening the frame. Take out the print and wash it in a tray of clean water, wearing gloves, until the yellow is gone from the light areas; Ware estimates about 20 minutes for the classic formula3. Water, oxidation and drying are covered in developing a cyanotype.

    How to tell it’s going well: the highlights stay white and the blue deepens as it dries.

    Safety: Keep leftover solution and the first wash bath in a closed, labeled container for your local hazardous waste collection point; later rinses can go down the drain with plenty of water. More on safety

365 or 395 nm: which wavelength to use#

For cyanotype, a 365 nm lamp is the better choice. According to the only peer-reviewed study we’ve found that measures the paper’s response, sensitivity peaks between 300 and 330 nm and drops as wavelength increases, so for the same energy 365 nm performs better than 395–405 nm1. But the actual time also depends on power and distance.

What ultraviolet light cyanotype usesWavelength axis from 280 to 450 nm with three bands: UVB, from 280 to 315 nm; UVA, from 315 to 400 nm; and visible light from 400 nm. Above it, a schematic paper sensitivity curve: highest between 300 and 330 nm and falling to nearly zero around 420–430 nm; only the peak and the cutoff are fixed. Marks for the LEDs on the market, at 365, 385, 395 and 405 nm; for the BL368 blacklight tube, peaking at 368 nm according to its manufacturer; and a band for nail lamps, about 340–395 nm depending on the unit. Note: for the same energy, 365 nm performs better than 395–405 nm; the actual time also depends on power and distance.UVBUVAvisiblePaper sensitivitySchematic curve: only the peak(300–330 nm) and the cutoff (around420–430 nm) are fixed.280300320340360380400420440nmLEDs on the market365385395405BL368 blacklight tube (peak)368Nail lamps (by unit)about 340–395 nmFor the same energy, 365 nm performs better than 395–405 nm; the actual time also depends on power and distance. What ultraviolet light cyanotype usesUVBUVAvisiblePaper sensitivity (schematic curve: only thepeak and cutoff are fixed)280320360400440LEDs on the market: 365, 385, 395 and 405 nm(dotted lines)BL368 blacklight tube: peak at 368 nm(solid line)Nail lamps: about 340–395 nm, dependingon the unit (band)For the same energy, 365 nm performs better than395–405 nm; the actual time also depends on powerand distance.
Diagram 1What ultraviolet light cyanotype uses. Where each lamp falls relative to the paper’s sensitivity: the shorter the wavelength within UVA, the better it performs.

A nanometer (nm) is a millionth of a millimeter, and the wavelength tells you which part of the spectrum the lamp emits in. The WHO places UVA between 315 and 400 nm13, and that’s the band where the ultraviolet LEDs on the market sit: a review of cyanotypes in the classroom mentions 365, 385, 395 and 405 nm LEDs, and warns that with those at the violet end the exposure can get longer14.

Above about 420–430 nm, light barely forms any Prussian blue1. A 405 nm lamp is therefore at the edge of the useful band. A 395 nm lamp works, but needs a larger dose for the same result; how much larger depends on the unit.

Wavelength: what gets passed around and what the sources say
What you’ll hear What the sources say Source
365 nm matches cyanotype’s peak sensitivity The measured peak is at 300–330 nm; 365 nm is within the useful band, but it isn’t the peak 1
A 395 nm lamp always needs a fixed percentage of extra time We haven’t found that percentage in reliable sources: without fixing power and distance, it makes no sense 1,2
Cyanotype only responds to 365 nm It responds across all the ultraviolet tested and somewhat in the violet; barely above about 420–430 nm 1

Herschel saw this as early as 1842: his mixture formed Prussian blue under the blue and violet rays, and under those he called “extra-spectral,” beyond the violet15. The ultraviolet from today’s LEDs is the same radiation Herschel detected beyond the violet.

Can you make cyanotypes with a nail lamp?#

A nail lamp can work for small pieces, but it depends on the unit. Gel lamps emit long-wave ultraviolet, roughly between 340 and 395 nm16, and each model has its own spectral distribution17. We haven’t found any study measuring their use for cyanotype, so we don’t give times.

A Spanish study measured 28 units from beauty salons and found that each one emitted its own particular spectrum; in the LED units, emission was centered in the visible range17. Another study on nail salons describes these devices as ultraviolet sources with significant blue light emission18. Visible light does little for cyanotype, which is why some nail lamps work and others barely do.

If you want to try, check the wavelength the manufacturer states, use only the opening of the unit for a piece that fits entirely inside, and make a long test strip. And treat it like any other UV lamp: don’t put your hands in or look inside while it’s on.

Does a blacklight work?#

It depends on the blacklight. Classic blacklight tubes are low-pressure mercury vapor fluorescents with a phosphor that emits ultraviolet A19; some peak near 365 nm, like Sylvania’s BL368 tube, which peaks at 368 nm according to the manufacturer20. Other bulbs and flashlights sold under that name are LEDs, and ultraviolet LEDs are also made at 385, 395 and 405 nm, toward the violet14.

None of the tube datasheets we consulted mentions cyanotype: they’re designed for other uses, such as attracting insects20. Before buying one, look for the wavelength on the manufacturer’s datasheet, not in the product name.

How to protect your eyes and skin with the lamp#

With a lamp, the order you work in protects you from almost everything: switch it on with the print in place, don’t look at it, step out of the beam and switch it off before going near it. 365 nm radiation is UVA, and the lens of the eye absorbs almost all radiation from 300 to 370 nm; UV exposure speeds up the onset of some cataracts21.

If you work next to the lamp, wear safety glasses that block UV. ANSI Z87.1 grades UV filter lenses from U2 to U6: the higher the number, the less near UV gets through12. Ordinary prescription glasses made of regular glass aren’t enough: ICNIRP notes that window glass transmits radiation above about 310 nm21, so it doesn’t guarantee protection at 365 nm.

The WHO classifies ultraviolet radiation as carcinogenic to humans22, so we don’t repeat what some manufacturers say about 365 nm UVA, which they present as harmless. If you take a medication whose leaflet warns about photosensitivity, ask your pharmacist before long sessions: some drugs make the skin sensitive to UV, especially UVA21. All the details are in UV light safety.

If something goes wrong#

These are the most likely problems with a lamp, and where to start looking:

If you want an enclosed, fixed station for long series, the UV exposure box page explains when it’s worth it. And if one day you’d rather use the sun despite the clouds, the page on cyanotype on a cloudy day explains what changes.

Frequently asked questions

How far away should the UV lamp be for cyanotype?

There’s no universal distance: it depends on your lamp’s power and the size of the print. As a basic guide, the Science and Media Museum gives a 125 W lamp at about 45 cm for the classic formula. What matters is to fix a distance that covers the whole format, measure it and not change it between the test strip and the print.

How long do you expose a cyanotype under a UV lamp?

It depends on the formula and the lamp. With the classic formula, Mike Ware estimates about 20–30 minutes and the museum gives about 30 minutes as a guide; Ware’s formulas need less, from 2 to 10 minutes depending on the variant. Your actual time comes from a test strip made with your lamp at your distance.

Do sunglasses work for working with a UV lamp?

For a lamp, safety glasses that block UV are the better choice. With a clear lens they let you see the color of the print properly. Even with glasses, what protects you most is not looking at the lamp and switching it off before you go near it.

Why don’t I get anything with my blacklight or UV flashlight?

Probably not enough energy is reaching the useful range. There are 365 nm ultraviolet LEDs, but also 385, 395 and 405 nm ones, toward the violet, where cyanotype is less sensitive; if the lamp is also low-powered or far away, the dose falls short. Check the wavelength the manufacturer states and make a long test strip.

Can you expose cyanotype on fabric with a UV lamp?

Yes, the setup is the same as for paper: the dry coated fabric goes under the glass, with the lamp above, always at the same distance. Since each fabric can respond differently, make the test strip with a scrap of the same fabric, coated from the same batch of solution as the piece.

Your next step

Set up the contact frameWhich glass to use for exposing cyanotypes, glass or acrylic, how to build the contact sandwich and a homemade clip press for sharp edges.

Sources

  1. Turner, J., Parisi, A. V., Downs, N. and Lynch, M. (2014). From ultraviolet to Prussian blue: A spectral response for the cyanotype process and a safe educational activity to explain UV exposure for all ages. Photochemical & Photobiological Sciences, 13(12), 1753-1764. https://doi.org/10.1039/c4pp00166d 12345678
  2. International Union of Pure and Applied Chemistry. (2025). Radiant exposure, H. In Compendium of chemical terminology (5th ed., online version 5.0.0). https://goldbook.iupac.org/terms/view/R05042 Accessed October 16, 2026. 12
  3. Ware, M. (n.d.). The traditional cyanotype process. Mike Ware: Alternative photography. https://mikeware.co.uk/mikeware/Traditional_Cyanotype.html Accessed October 16, 2026. 12
  4. National Science and Media Museum. (2011, February 18). Introduction to the cyanotype process. National Science and Media Museum Blog. https://blog.scienceandmediamuseum.org.uk/introduction-cyanotype-process/ Accessed October 17, 2026. 12345
  5. Ware, M. (n.d.). The New Cyanotype process. Mike Ware: Alternative photography. https://www.mikeware.co.uk/mikeware/New_Cyanotype_Process.html Accessed October 16, 2026. 123
  6. Ware, M. (2022). Alternative photographic processes: Simple Cyanotype [PDF instructions]. https://mikeware.co.uk/downloads/SimpleCy22.pdf Accessed October 16, 2026. Cited: p. 11. 12
  7. Scientific Committee on Emerging and Newly Identified Health Risks (SCENIHR). (2012). Health effects of artificial light [Lay summary]. European Commission. https://ec.europa.eu/health/scientific_committees/opinions_layman/artificial-light/en/l-3/7-health-risks.htm Accessed October 16, 2026.
  8. Reeder, R. and Anderson, C. Z. (2013). How to make digital negatives [Excerpt]. In C. Z. Anderson, Gum printing and other amazing contact printing processes. Reproduced on Freestyle Photographic Supplies. https://www.freestylephoto.com/alternative-process/making-digital-negatives
  9. Ware, M. (2009). New Cyanotype: Siderotype workshop notes. https://www.mikeware.co.uk/downloads/CyanoWork.pdf Accessed October 17, 2026. 12
  10. Ilford Photo. (2017, March 30). Making a black & white print: Exposure testing. https://www.ilfordphoto.com/exposure-testing/ Accessed October 16, 2026.
  11. Jacquard Products. (2021). Cyanotype detailed instructions [Manufacturer’s instructions, version 08.17.21]. https://cdn.shopify.com/s/files/1/0053/5540/5423/files/Cyanotype_Instructions.pdf Accessed October 16, 2026. 12
  12. Bullard. (n.d.). Z87.1 marking [Product information]. https://apac.bullard.com/products/eye-protection/z87-1-marking/ Accessed October 24, 2026. 12
  13. World Health Organization. (n.d.). Ultraviolet radiation [Health topic]. https://www.who.int/health-topics/ultraviolet-radiation Accessed October 17, 2026.
  14. Redden, H. and Crawford, A. (2025). Anna Atkins and the making of macroalgae cyanotypes and their role in science education. Applied Phycology, 6(1), 1-8. https://doi.org/10.1080/26388081.2024.2435049 12
  15. Ware, M. (2014). Cyanomicon: History, science and art of cyanotype: Photographic printing in Prussian blue (rev. and expanded ed.). https://www.mikeware.co.uk/mikeware/downloads.html Cited: p. 34.
  16. Zhivagui, M., Hoda, A., Valenzuela, N., Yeh, Y.-Y., Dai, J., He, Y., Nandi, S. P., Otlu, B., Van Houten, B. and Alexandrov, L. B. (2023). DNA damage and somatic mutations in mammalian cells after irradiation with a nail polish dryer. Nature Communications, 14(1), Article 276. https://doi.org/10.1038/s41467-023-35876-8
  17. Baeza, D., Sola, Y., del Río, L. A. and González, R. (2018). Nail dryer devices: A measured spectral irradiance and labelling review. Photochemical & Photobiological Sciences, 17(5), 592-598. https://doi.org/10.1039/c7pp00388a 12
  18. Lee, S., Gaskin, S., Piccoli, B. and Pisaniello, D. (2022). Blue light exposure in the workplace: A case study of nail salons. Archives of Environmental & Occupational Health, 77(5), 351-355. https://doi.org/10.1080/19338244.2021.1924604
  19. Signify. (2023, April 14). TL-D 36W BLB 1SL/25 [Datasheet, in French]. Philips Lighting. https://www.assets.lighting.philips.com/is/content/PhilipsLighting/fp928048510805-pss-fr_ch Accessed October 16, 2026.
  20. Sylvania. (2026). F6W T5 BL368: Datasheet. https://staticdatasheets.sylvania-group.com/datasheets/en-ee_0000088.pdf Accessed October 16, 2026. 12
  21. International Commission on Non-Ionizing Radiation Protection. (2010). ICNIRP statement: Protection of workers against ultraviolet radiation. Health Physics, 99(1), 66-87. https://doi.org/10.1097/HP.0b013e3181d85908 123
  22. World Health Organization. (2022, June 21). Ultraviolet radiation [Fact sheet]. https://who.int/news-room/fact-sheets/detail/ultraviolet-radiation Accessed October 16, 2026.

Reviewed on October 16, 2026. If you spot an error or a missing source, write to us and we’ll look into it.