The Journal: The Cyano Codex blog · No. 18
From the ferrioxalate actinometer to cyanotype: the chemistry that measures light
- Section
- The Journal
- Published
- Reviewed
- Reading time
- 8 min
- Sources
- 12
As an Amazon Associate I earn from qualifying purchases. How we fund the site
In short
- Herschel was trying to record the invisible rays of the spectrum, and cyanotype came out of that search.
- Bunsen and Roscoe measured the chemical action of light with chlorine and hydrogen in 1856–1857.
- The ferrioxalate actinometer, by Parker and by Hatchard and Parker, is the most widely accepted standard, according to IUPAC.
On this page (6 sections)
Rays you can’t see, but that act#
At the start of the 19th century, the two invisible kinds of radiation on either side of the visible spectrum had just been discovered: infrared (1800) and ultraviolet (1801). William Herschel had discovered infrared in 1800, and in 1801 Johann Wilhelm Ritter discovered ultraviolet, then called “actinic” rays, the ones that act1. John Herschel, William’s son, wanted to record that invisible radiation, and cyanotype came out of that search1.
He put it in writing in his 1842 paper: the mixture of ferric ammonium citrate and ferricyanide formed an abundant deposit of Prussian blue under the blue, violet and “extra-spectral” rays, beyond the violet2. And he found something modern chemistry confirms: nearly all the light sensitivity came from the iron salt, not the ferricyanide2.
Iron and light, before cyanotype#
Herschel wasn’t starting from scratch. In 1831, Johann Wolfgang Döbereiner had observed that light makes ferrous oxalate precipitate from a solution of ferric oxalate, and Herschel knew that work1. Ferric means iron(III); ferrous, iron(II). It’s the same transformation that, some hundred and twenty years later, would give photochemists their measuring tool.
Today we know why oxalate and citrate make iron light-sensitive. The iron(III) complexes with these molecules, from the carboxylate family, absorb light through ligand-to-metal charge transfer: an electron jumps from the molecule surrounding the iron to the iron itself, and the bond breaks3. In cyanotype, that freshly formed iron(II) meets the ferricyanide and forms the blue4.
Measuring light with instruments and with chemistry#
Measuring incoming light was a concern of the period. The Science Museum Group holds two “Herschel type” actinometers, one by Thomas Charles Robinson, from 1840, and another by Henry Barrow, from 1848, which came from the British Meteorological Office5. Their catalog record doesn’t explain how they worked, so we don’t either.
Chemical measurement came soon after. In November 1856, Robert Bunsen and Henry Enfield Roscoe sent the Royal Society the first part of their photochemical researches, devoted to measuring the chemical action of light6. Their system was a mixture of equal volumes of pure chlorine and hydrogen6.
Ferrioxalate, the photochemists’ standard#
According to IUPAC, an actinometer is a chemical system or physical device used to determine how many photons in a beam are absorbed; in a chemical one, the amount the light transforms depends directly on those photons7. A photon is one of the packets of energy that light is made of.
Today’s standard was born in the 1950s. In 1953, Eric Rideal signed the referee report recommending publication of C. A. Parker’s first paper on a new potassium ferrioxalate actinometer8. IUPAC cites that work and the second part, by C. G. Hatchard and Parker, from 19567. In 2004 it described it as the most widely accepted standard chemical actinometer, useful between 250 and 500 nm7.
The method looks nothing like a cyanotype. The ferrioxalate solution is irradiated, the iron(II) formed is converted into a complex with 1,10-phenanthroline, and the light absorbed by that complex is measured at 510 nm; all the work is done under dim red light7. In 2018, a spectroscopy study was still calling it the “gold standard” of solution-phase actinometry9.
Same reaction, different use#
The actinometer and cyanotype share the first step and then part ways right away. In both, light converts iron(III) into iron(II)9,10. But the actinometer measures that iron in a solution that absorbs all the light, while cyanotype turns it into a pigment on a sheet of paper.
That’s why the actinometer’s 250 to 500 nm range doesn’t apply to blue paper. The only peer-reviewed study we’ve found that measures the spectral response of cyanotype paper found it peaked between 300 and 330 nm and was practically exhausted above about 420–430 nm11. Herschel had already placed that action at the blue and violet end of the spectrum and beyond2.
The closest kinship is in a variant. The New Cyanotype that Mike Ware published in 1995 uses ferric ammonium oxalate instead of the citrate in the classic formula12: the same kind of iron–oxalate complex that Döbereiner studied and that underlies the actinometer. Its chemistry and precautions are covered in Ware’s New Cyanotype.
Back to blue: measuring with paper#
In 2014, Turner and colleagues proposed commercial cyanotype paper as an activity for explaining exposure to ultraviolet radiation11. They found that it responded linearly to dose in short exposures and didn’t react in the dark, although with a limited range that varied by manufacturer and batch11.
It isn’t an actinometer, and the authors don’t present it as one. But it makes historical sense: Herschel wanted to record invisible radiation, and today that same paper is used in the classroom to show how much ultraviolet light gets through. How to set up that measurement with a group, with filters, a series of pieces and a graph, is in the cyanotype lab activity for chemistry class.
More from the Journal
- No. 20Rauschenberg and Weil: full-body cyanotypes around 1950How Robert Rauschenberg and Susan Weil made their full-body cyanotypes around 1950, where they were shown in 1951 and which museums hold them today.
- No. 19Meghann Riepenhoff: cyanotypes made with waves, salt and sandHow Meghann Riepenhoff makes her Littoral Drift cyanotypes with waves, salt and sand, why they change with light and which museums show them.
Frequently asked questions
What is an actinometer?
It’s a chemical system or physical device used to find out how many photons in a beam of light are absorbed. In a chemical actinometer, the amount of substance the light transforms is directly related to the number of photons absorbed, and that makes it possible to measure light with a reaction.
Can cyanotype be used as an actinometer?
Not strictly. Cyanotype paper responds linearly to dose in short exposures, but it has a limited range and varies between manufacturers and batches. That’s why it’s used for teaching or comparison, while laboratory measurement is done with the ferrioxalate actinometer, in solution.
What does New Cyanotype have to do with the actinometer?
They belong to the same chemical family. Mike Ware’s New Cyanotype uses ferric ammonium oxalate instead of citrate, and the standard actinometer uses potassium ferrioxalate. In both, light converts the oxalate-bound iron(III) into iron(II).
Who invented the ferrioxalate actinometer?
C. A. Parker published the first part of the work in 1953, after a referee report by Eric Rideal recommending publication, and C. G. Hatchard and Parker published the second in 1956. IUPAC cites both papers when describing it as the most widely accepted standard chemical actinometer.
Your next step
Sources
- Ware, M. (1998). Herschel's cyanotype: Invention or discovery? History of Photography, 22(4), 371-379. https://doi.org/10.1080/03087298.1998.10443901 123
- Ware, M. (2014). Cyanomicon: History, science and art of cyanotype: Photographic printing in Prussian blue (rev. and expanded ed.). https://www.mikeware.co.uk/mikeware/downloads.html 123
- Chaudhuri, A., Denkler, L. M., Zhuo, Q., Mandal, A. and Bunescu, A. (2025). LMCT-driven iron photocatalysis: Mechanistic insights and synthetic applications. Chemistry – A European Journal, 31(58), Article e02185. https://doi.org/10.1002/chem.202502185
- Sentoku, S., Kurashina, M. and Kida, K. (2025). Observation of blue particles formed by photosensitizing reaction on paper fibres of cyanotypes. Photochem, 5(3), Article 18. https://doi.org/10.3390/photochem5030018
- Robinson, T. C. and Barrow, H. (1840-1848). 2 Herschel type actinometers [Scientific instruments]. Science Museum Group, London, 1957-103. https://collection.sciencemuseumgroup.org.uk/objects/co54617/2-herschel-type-actinometers Accessed October 18, 2026.
- Bunsen, R. and Roscoe, H. E. (1857). Photo-chemical researches.—Part I. Measurement of the chemical action of light. Philosophical Transactions of the Royal Society of London, 147. https://doi.org/10.1098/rstl.1857.0018 12
- Kuhn, H. J., Braslavsky, S. E. and Schmidt, R. (2004). Chemical actinometry (IUPAC Technical Report). Pure and Applied Chemistry, 76(12), 2105-2146. https://publications.iupac.org/pac/2004/7612/7612x2105.html 1234
- Parker, C. A. (1953). A new sensitive chemical actinometer. I. Some trials with potassium ferrioxalate. Proceedings of the Royal Society of London. Series A, 220, 104-116. https://doi.org/10.1098/rspa.1953.0175
- Straub, S., Brünker, P., Lindner, J. and Vöhringer, P. (2018). Femtosecond infrared spectroscopy reveals the primary events of the ferrioxalate actinometer. Physical Chemistry Chemical Physics, 20(33), 21390-21403. https://doi.org/10.1039/C8CP03824D 12
- Stulik, D. C. and Kaplan, A. (2013). Cyanotype. In The atlas of analytical signatures of photographic processes. Getty Conservation Institute. https://www.getty.edu/conservation/publications_resources/pdf_publications/pdf/atlas_cyanotype.pdf
- Turner, J., Parisi, A. V., Downs, N. and Lynch, M. (2014). From ultraviolet to Prussian blue: A spectral response for the cyanotype process and a safe educational activity to explain UV exposure for all ages. Photochemical & Photobiological Sciences, 13(12), 1753-1764. https://doi.org/10.1039/c4pp00166d 123
- Ware, M. (2009). New Cyanotype: Siderotype workshop notes. https://www.mikeware.co.uk/downloads/CyanoWork.pdf Accessed October 17, 2026.
Reviewed on October 17, 2026. If you spot an error or a missing source, write to us and we’ll look into it.